THE
PROBLEM
The National Oceanic and Atmospheric
Administration (NOAA) mission is to protect
life and property, and enhance the United
States’ economy. NOAA’s National Weather
Service is the sole official voice of
the U.S. government for issuing public
safety warnings during life-threatening
weather situations. Their technology
requires a dedicated 4 Wire analog connection
from their source stations to a broadcast
point in the field to provide critical
emergency information to the public.
These circuits require a constant analog
carrier tone to be delivered from the
source to the transmitter, which is interrupted
during voice transmissions. Due to the
forthcoming phase out of copper wire
line based phone circuits, and these
phone lines becoming less dependable
and requiring longer time for repair
of down circuits – they must be replaced
with more economical and reliable service.
The problem - how to move the existing
analog based signaling system from a
copper phone line based service to a
cost effective, secure, dependable digital
IP backhaul without disrupting the existing
network or requiring an expensive forklift
up grade?
THE SOLUTION
The Encore Networks BANDIT-3™ router
providing Internet Protocol (IP), VPN,
Firewall, Ethernet Switching, legacy
serial protocol with analog circuit
interworking using an integrated 3G
cell modem. A single box solution that
supports traditional 2/4 Wire analog
circuit interworking to an IP solution,
without changing any equipment in the
field while preserving the invested
CAPEX. The BANDIT-3™ 4 Wire interface
supports the analog tone frequency
requirements, while packetizing it
for transmission over the 3G cellular
network using a secure VPN with IPSEC
encryption to ensure end to end security.
The switch from a copper phone line
to a cellular data connection was done
simply by unplugging the existing analog
equipment from the copper line and
terminating it on the BANDIT-3™. With
its Ethernet Switching ports, the BANDIT-3™
is able to deliver IP/Ethernet based
services at anytime at a fraction of
the cost.
APPLICATION DIAGRAM

TECHNICAL
SPECIFICATIONS
Physical Ports
Serial
• 1 universal
DB25 port (RS232)
• Optional four DB25 ports (RS232)
• 1 RS232 console
Modem - Optional
• integrated 56Kbps V.90/92 with PPP
support (PAP/CHAP)
Ethernet
• 4 10/100 Base T - 3 switched and
1 configurable
Expansion Slot
• Dual Port Fiber Module – Multimode
or Single Mode SFPs
• Single T1/E1 CSU/DSU channelized/unchannelized
• Dual T1/E1 CSU/DSU channelized/unchannelized
• 56/64k CSU/DSU
• Ethernet DMZ
• Single Port High Speed Serial (V.35,
RS 485, RS 422)
• Dual Port 4 Wire E&M
- 600 ohm input impedance
- Adjustable transmit and receive gain
in 0.2 dB steps
-Transmit at 6 dB
- Receive at 5 dB
- Idle Channel Noise, C-message Weighted < 18
dBrnc0
- Supports the following CODEC types:
- ITU G.726 - 16/24/32 kbps
- Selectable frame size
- Automatic Clock recovery for end-to-end
synchronization
Alarm Port
• Programmable alarm indicators
Optional Cellullar Modem
• EVDO
Security Appliance Features
• Integrated router/firewall/VPN
• DMZ LAN port
• NAT
• VPN (up to 30 tunnels)
- IP Sec (RFC 2401) with DES, 3DES
and AES (256)
- GRE (RFC 1701)
- Internet Key Exchange - IKE (RFC
2409)
• Selective Layer Encryption
(SLE)
Protocols
WAN
• Frame Relay (RFC1490)
• Asynchronous PPP
• Synchronous PPP
• X.25
• MLPPP
• MPLS
IP
• IP Routing (RIP v1/v2) or static
routing
• DHCP client/server/BootP/Relay
• IP QoS and traffic prioritization
• IP fragmentation/reassembly
• IP routing over VPN
• VRRP (RFC3768)
Ethernet
• 802.1q VLAN tagging
• PPPoE
Serial Legacy Support
• Up to 5 DB25 ports supporting
EIA/TIA RS485,RS232, RS422
• Supports any asynchronous
or synchronous traffic over IP.
• Legacy Protocol
Electrical
• 10 Watts maximum
• DC: 12VDC, 24VDC, 48VDC,
130VDC, 250VDC
• AC: 100-240VAC, 50-60Hz
(with external adapter)
Environmental
• Operating: -40°C to +85°C
• Storage: -40°C to +85°C
• Humidity: 5 to 95%, non-condensing
Mechanical
• Height: 2.375” (6.0 cm)
• Width: 10.375” (26.4 cm)
• Depth: 7.5” (219.1 cm)
• Weight: 2.25 lb. (1.02
kg)
Standards Compliance
RoHS Compliant
EMC
• FCC Part 15
• EN 55011/CISPR II
• IEC 61850-3
• IEEE 1613
Product Safety
• UL/CSA 60950-1
• CAN/CSA-C22.2 No. 60950-1-03
• EN 60950-1
Part Number
• B3000-0000-0000-0 |