EXTENSIVE
PROTOCOL SUPPORT
The following protocols are available,
as well as a wide variety of custom variants:
• ANSI SS7/ITU C7
• ANSI SS7/NI2 ISDN
• ANSI SS7/ETSI ISDN
• ITU C7/ETSI ISDN
SUPERIOR
MAINTENANCE AND DIAGNOSTICS
• Multiple maintenance features enable quick and cost-effective resolution
of network problems.
• Trace functionality is available to aid in trouble- shooting configuration
and network problems.
• Visual and dry contact alarms allow for remote and local monitoring.
• Remote management capabilities enable out-ofband console port access.
COMPACT
CHASSIS DESIGN
• The SP201-Z features a compact 1U height designed for budgeted space,
with a capacity of up to four E1 or T1 interfaces for carrier locations with
low-end requirements.
• Chassis-based, the SP201-Z is designed specifi cally for today’s high
standards in the communications environment.
OTHER PRODUCT
FEATURES
• Standard connections (RJ48, BNC)
• Up to four E1 or T1 trunks (full duplex, eight ports)
• Up to 120 DS0s per chassis
• DPC routing
• ANI substitution |
TECHNICAL
SPECIFICATIONS
STANDARDS
CONFORMANCE
SS7:
BellCore TR-NWT-00246, ANSI T1.111a, T1.112, T1.113a, T1.114,
T1.116, T1.234–T1.236
C7:
ITU-T White Book: Q.767, Q.701– Q.704, Q.705, Q.708, Q.709,
Q.780–Q.782, Q.784, Q.788
ETSI ISDN:
ETSI 300-102, Q.931, Q.921
NI2 ISDN:
BellCore TR-NWT-001268, TR-NWT-002343; Q.931, Q.921
AGENCY COMPLIANCE
Safety:
EN 60950, European Safety (CE Mark)
UL 1950 3rd Edition, U.S. Safety
Emissions:
EN 55022: 1998 (Europe); FCC Part 15, Sub-Part B, Class A (U.S.)
Immunity:
EN55024: 1998
Belcore Emissions & Immunity:
GR-1089-CORE, Section 3
PHYSICAL SPECIFICATIONS
Height: 1.75
in. (4.45 cm)
Width: 19
in. (48.26 cm)
Depth: 10
in. (25.4 cm)
Input
Power:
-42 to -56 VDC
100 to 240 VAC, 50 to 60 Hz
Temperature: 32° to 122° F (0°
to 50° C)
Humidity: Up to 95% non-condensing
Altitud: Up to 10,000 ft. (3,048
m)
SYSTEM CAPACITY
Interfaces: Up
to four E1 or T1 trunks (or eight full
duplex trunks) per chassis
Channels: Up
to 31 per trunk; up to 248 per chassis
SS7/C7: Four
per chassis
ISDN D Channels: Four
per chassis
Destination Point Codes: One
per trunk; up to 4 per chassis
INTERFACE
SPECIFICATIONS
Framing:
E1: G.732 or G.706
T1: D4SF or D4ESF
Bit Rate:
E1: 2,048 Mbps
T1: 1.544 Mbps
Clocking:
E1: ± 30 ppm internal
E1: ± 100 ppm external
T1: ± 30 ppm internal
T1: ± 150 ppm external
Impedance:
E1: 120 ohm balanced
E1: 75 ohm unbalanced
T1: 100 ohm balanced
Coding:
E1: AMI or HDB3 T1: AMI or B8ZS
Alarms:
E1: Loss of carrier signal, multi-frame carrier signal, sync;
alarm indication signal (AIS); receipt of remote alarm; receipt of multi-frame
remote alarm
T1: Loss of carrier signal; loss of frame; receipt of alarm indication
signal (AIS); receipt of remote alarm
Diagnostics:
E1/T1: signaling state report, digit report
Performance:
E1: G.703, G.706, G.732, G.823 T1: ATT Pub. 6241 |