| SignalPath 201
Product Overview |
|
|
 |
The SignalPath 201
(SP201) is an advanced signaling protocol
converter designed to facilitate interoperability
between incompatible communication networks.
The SP201 enables a seamless interface between
in-band and out-of-band networks, and between
out-of-band networks and other out-of-band
networks.
Different types of communication
protocols, both in-band and out-of-band,
exist globally. One country could have
up to six or seven different protocols
simultaneously in use within its networks.
The SP201 breaks down the communication
barriers presented by these different protocols
and enables the flow of information across
any network.
Not only can you increase
your potential to connect to a larger portion
of the world market, but you can also eliminate
charges you may be currently paying to
one or more companies for network connections.
This means more revenue in your corporate
pocket. |
|
|
| EXTENSIVE
PROTOCOL SUPPORT |
|
|
| COMPACT
CHASSIS DESIGN |
 |
The
SP201 features a compact 1U height designed
for budgeted space, with a capacity of
up to 4 E1 or T1 interfaces for the customer
with low-end requirements. |
 |
Chassis-based,
the SP201 is designed specifically for
today's high standards in the communications environment. |
|
|
| SUPERIOR
MAINTENANCE AND DIAGNOSTICS |
 |
Multiple maintenance features
enable quick and cost-effective resolution
of network problems. |
 |
Trace
functionality is available to aid in troubleshooting
configuration and network problems. |
 |
Visual and dry contact alarms
allow for remote and local monitoring |
|
|
| OTHER
PRODUCT FEATURES |
 |
Standard RJ48 connections |
 |
p
to 4 E1 or T1 trunks |
 |
Up to 124 DS0s
per chassis |
 |
Dynamic
bi-directional µ-Law/A-Law T1/E1
conversion |
 |
Cross-connect
and circuit mapping capability |
 |
19
in. (48.26 cm) rack-mountable chassis |
 |
Option of either
-48 VDC or 120/240 VAC power input |
|
|
| |
| Specifications |
| |
| STANDARDS
CONFORMANCE |
| R1 |
Q.310-Q.331 R2 Q.400-Q.490 |
| R2 |
Q.400-Q.490 |
| DTMF |
BellCore TR-TSV-002275,
Subsection 6.13 |
| SS7 |
BellCore TR-NWT-00246,
ANSI T1.111a, T1.112, T1.113a, T1.114,
T1.116, T1.234-T1.236 |
| C7 |
ITU-T
White Book: Q.767, Q.701- Q.704, Q.705,
Q.708, Q.709, Q.780- Q.782, Q.784, Q.788 |
| ISDN-ETSI |
ETSI 300-102, Q.931,
Q.921 |
| ISDN-NI2 |
BellCore
TR-NWT-001268, TR-NWT-002343; Q.931,
Q.921 |
|
| |
|
| AGENCY
COMPLIANCE |
| Safety |
EN 60950, European
Safety (CE Mark) |
| |
UL
1950 3rd Edition, U.S. Safety |
| Emissions |
EN
55022, Class A
FCC Part 15, Sub-part B, Class A |
| Immunity |
EN55024:
1998 |
Bellcore
Emissions & Immunity |
GR-1089-CORE,
Section 3 |
|
| |
|
| HARDWARE
SPECIFICATIONS |
Physical |
|
Height |
1.75
in. (4.45 cm) |
Width |
19
in. (48.26 cm) |
Depth |
10
in. (25.4 cm) |
| Input
Power |
-42 to -56 VDC
100 to 240 VAC, 50 to 60 Hz |
| Environmental |
|
Temperature |
32° to
122° F (0° to 50° C) |
Humidity |
Up to 95% non-condensing |
Altitude |
Up
to 10,000 ft. (3,048 m) |
|
|
|
|
| SYSTEM
CAPACITY |
Aggregate
Cards |
One per chassis |
| Interfaces |
Up
to four E1 or T1 trunks (or eight full
duplex trunks) per chassis |
| Channels |
Up to 31 per trunk; up
to 248 per chassis |
SS7/C7
Signaling
Links |
4 per
chassis |
|
| |
| INTERFACE
SPECIFICATIONS |
Framing |
E1: G.732 or G.704
T1: D4SF or D4ESF |
| Bit
Rate |
E1:
2,048 Mbps
T1: 1.544 Mbps |
| Clocking |
E1: +/- 30 ppm internal
E1: +/- 100 ppm external
T1: +/- 30 ppm internal
T1: +/- 150 ppm external |
| Impedance |
E1:
120 ohm balanced
E1: 75 ohm unbalanced
T1: 100 ohm balanced |
| Coding |
E1: AMI or HDB3
T1: AMI or B8ZS |
| Alarms |
E1:
Loss of carrier signal, multi-frame
carrier signal, sync; alarm indication
signal (AIS); receipt of remote alarm;
receipt of multi-frame remote alarm
T1: Loss of carrier signal; loss of
frame; receipt of alarm indication signal (AIS); receipt
of remote alarm |
| Diagnosis |
E1/T1: signaling state
report, digit report |
| Performance |
E1:
G.703, G.704, G.732, G.823
T1: ATT Pub. 62411 |
|
|
|
| |
|
|